Mineral Insulated Fire Resistant Cables · Mineral Insulated Fire Resistant Cables · Mineral Insulated Fire Resistant Cables · Mineral Insulated Fire Resistant Cables · Mineral Insulated Fire Resistant Cables · Mineral Insulated Fire Resistant Cables · Mineral Insulated Fire Resistant Cables · Mineral Insulated Fire Resistant Cables · Mineral Insulated Fire Resistant Cables · Mineral Insulated Fire Resistant Cables · Mineral Insulated Fire Resistant Cables · Mineral Insulated Fire Resistant Cables · Mineral Insulated Fire Resistant Cables · Mineral Insulated Fire Resistant Cables · Mineral Insulated Fire Resistant Cables · Mineral Insulated Fire Resistant Cables ·
Mineral Insulated Fire Resistant Cables
Home / Products / Fire Resistant Cables / Mineral Insulated Fire Resistant Cables / Flexible Mineral Insulated Fire Resistant Cable BBTRZ

Flexible Mineral Insulated Fire Resistant Cable BBTRZ


Mold: BBTRZ

Flexible Mineral Insulated Fire-Resistant Cable BBTRZ is a high-performance fire-resistant cable developed for reliable power transmission under extreme conditions. It combines flexible structure with mineral insulation technology to provide strong fire resistance, stable electrical performance, and easier installation compared with traditional rigid fire-resistant cables.

Core Product Features
High Temperature Fire Resistance: Maintains normal power operation for 3 hours under 950°C flame conditions, with CWZ performance including fire, water spray, and impact resistance.
Flexible Long-Length Design: Supports continuous cable production in long coils with fewer intermediate joints, reducing potential connection risks during installation.
Smoke-Free Safety Performance: Uses inorganic mineral insulation that produces no smoke, acidic gases, or toxic substances during fire conditions.
High Current Carrying Capability: Provides higher load capacity under the same conductor size with strong resistance to temperature rise during short-circuit conditions.
Easy Installation Performance: Flexible cable structure provides a smaller bending radius and supports installation methods similar to conventional power cables.

OEM Customization Options
Flexible Mineral Insulated Fire Resistant Cable supports customized solutions for different project and brand requirements:
Structure Customization: Supports conductor specifications, insulation thickness, cable structure, and material adjustments.
Appearance Customization: Provides cable printing, LOGO marking, and identification information.
Length Customization: Supports customized cable lengths starting at 100 meters to meet project requirements.
Packaging Customization: Offers packaging solutions based on transportation and storage needs.
Project Support: Provides batch production, technical documents, and specification matching services for contractors and distributors.

Application Scenarios
Parameter Details
FAQ

Flexible Mineral Insulated Fire Resistant Cable is widely used in critical electrical systems where continuous operation during fire conditions is required:
High-Rise Buildings: Applied in emergency lighting, fire protection systems, and safety power circuits.
Hospitals and Public Facilities: Used for critical equipment and emergency power supply systems.
Transportation Projects: Suitable for tunnels, airports, and infrastructure facilities requiring reliable fire survival performance.
Industrial Facilities: Applied in factories and special environments with high fire safety requirements.

Model: BBTRZ
Specifications: 1×16–1×300 mm²
Single-core cable
Voltage rating: 0.6/1 kV

Specifications and Structural Description of Single-core Flexible Mineral-insulated Fire-resistant Cables

jtpatkhc1787554241 1. Copper conductor
2. Mineral-composite insulation
3. Fire-resistant layer
4. Wrapping tape
5. Low-smoke, halogen-free, flame-retardant sheath

Number of cores × cross-sectional area
(mm²)
Outer diameter of conductor
(mm)
Insulation outer diameter
(mm)
Thickness of inorganic mineral fireproof layer
(mm)
Outer sheath thickness
(mm)
Cable reference outer diameter
(mm)
Approximate weight of cable
(kg/km)
DC resistance of a conductor at 20 °C
(Ω/km)
Cable current-carrying capacity in air at an ambient temperature of 40 °C A
1×2.5 1.75  3.6  1.5  1.4  10.9  136.4  7.41  31 
1×4 2.2  4.0  1.5  1.4  11.4  157.1  4.61  41 
1×6 2.7  4.5  1.5  1.4  11.9  183.1  3.08  52 
1×10 4.0  5.8  1.5  1.4  13.2  239.7  1.83  71 
1×16 5.01  6.8  1.5  1.4  14.2  309.7  1.15  92 
1×25 6.0  8.2  1.5  1.4  15.7  419.5  0.727  120 
1×35 7.1  9.3  1.5  1.5  16.9  530.4  0.524  150 
1×50 8.3  10.7  1.5  1.5  18.4  694.7  0.387  180 
1×70 10.0  12.6  1.5  1.6  20.4  915.0  0.268  230 
1×95 11.6  14.2  2.0  1.7  23.2  1219.4  0.193  285 
1×120 12.7  15.5  2.0  1.7  24.6  1476.6  0.153  335 
1×150 14.6  17.8  2.0  1.8  27.0  1809.9  0.124  385 
1×185 16.2  19.8  2.0  1.8  29.2  2183.8  0.0991  450 
1×240 18.5  22.3  2.0  1.9  31.8  2748.7  0.0754  535 
1×300 20.7  24.7  2.5  2.1  35.5  3427.2  0.0601  620 
1×400 23.5  27.9  2.5  2.2  38.9  4433.1  0.0470  720 
1×500 25.8  31.1  2.5  2.3  41.8  5428.1  0.0366  835 
1×630 28.9  34.6  3.0  2.4  46.6  6815.5  0.0283  960 

Model: BBTRZ
Specifications: 2 × 2.5 to 2 × 300 mm²
2-core cable
Voltage rating: 0.6/1 kV

Specifications and Structural Description of 2-core Flexible Mineral-Insulated Fire-Resistant Cables

wentwjap1787554749 1. Copper conductor
2. Mineral-composite insulation
3. Fire-resistant layer
4. Taping
5. Low-smoke, halogen-free, flame-retardant sheath

Number of cores × cross-sectional area
(mm²)
Outer diameter of conductor
(mm)
Insulation outer diameter
(mm)
Thickness of inorganic mineral fireproof layer
(mm)
Outer sheath thickness
(mm)
Cable reference outer diameter
(mm)
Approximate weight of cable
(kg/km)
DC resistance of a conductor at 20 °C
(Ω/km)
Cable current-carrying capacity in air at an ambient temperature of 40 °C A
2×2.5 1.75  3.6  1.5  1.7  15.5    325.1  7.41  33 
2×4 2.2  4.0  1.5  1.7  16.4    383.5  4.61  43 
2×6 2.7  4.5  1.5  1.7  17.4    455.7  3.08  55 
  2×10 4.0  5.8  1.5  1.7  20.0    628.5  1.83  76 
  2×16 5.0  6.8  2.0  1.7  23.0    887.1  1.15  97 
  2×25 6.0  8.2  2.0  1.7  25.8    1192.1  0.727  130 
  2×35 7.1  9.3  2.0  1.7  28.1    1497.6  0.524  160 
  2×50 8.3  10.7  2.0  1.8  31.1    1944.3  0.387  195 
  2×70 10.0  12.6  2.5  2.0  36.2    2678.9  0.268  245 
  2×95 11.6  14.2  2.5  2.1  39.6    3377.6  0.193  305 
  2×120 12.7  15.5  2.5  2.1  42.4    4049.9  0.153  355 
  2×150 14.6  17.8  3.0  2.3  48.4    5171.1  0.124  405 
  2×185 16.2  19.8  3.0  2.4  52.6    6227.0  0.0991  465 
  2×240 18.5  22.3  3.0  2.6  57.9    7780.1  0.0754  545 
  2×300 20.7  24.7  3.0  2.8  63.0    9442.4  0.0601  620 
  2×400 23.5  27.9  3.0  3.0  69.9  12098.7  0.0470  695 

Model: BBTRZ
Specifications: 3×1.5–3×400 mm²
3-core cable
Voltage rating: 0.6/1 kV

Specifications and Structural Description of 3-core Flexible Mineral-Insulated Fire-Resistant Cables

nrbcopau1787555013 1. Copper conductor
2. Mineral-composite insulation
3. Fire-resistant layer
4. Taping
5. Low-smoke, halogen-free, flame-retardant sheath

Number of cores × cross-sectional area
(mm²)
Outer diameter of conductor
(mm)
Insulation outer diameter
(mm)
Thickness of inorganic mineral fireproof layer
(mm)
Outer sheath thickness
(mm)
Cable reference outer diameter
(mm)
Approximate weight of cable
(kg/km)
DC resistance of a conductor at 20 °C
(Ω/km)

Cable current-carrying capacity in air at an ambient temperature of 40 °C

3×2.5 1.75  3.6  1.5  1.7  16.1  357.5  7.41  28 
3×4 2.2  4.0  1.5  1.7  17.1  429.5  4.61  37 
3×6 2.7  4.5  1.5  1.7  18.2  519.3  3.08  47 
3×10 4.0  5.8  1.5  1.7  21.0  725.6  1.83  65 
3×16 5.0  6.8  2.0  1.7  24.2  1037.6  1.15  84 
3×25 6.0  8.2  2.0  1.7  27.2  1423.0  0.727  110 
3×35 7.1  9.3  2.0  1.8  29.7  1814.1  0.524  135 
3×50 8.3  10.7  2.5  1.9  34.0  2491.6  0.387  170 
3×70 10.0  12.6  2.5  2.0  38.4  3295.3  0.268  215 
3×95 11.6  14.2  2.5  2.1  42.0  4201.5  0.193  265 
3×120 12.7  15.5  3.0  2.3  46.1  5227.5  0.153  310 
3×150 14.6  17.8  3.0  2.4  51.4  6460.5  0.124  350 
3×185 16.2  19.8  3.0  2.5  56.0  7806.6  0.0991  405 
3×240 18.5  22.3  3.0  2.7  61.7  9809.7  0.0754  480 
3×300 20.7  24.7  3.0  2.9  67.2  11964.6  0.0601  555 
3×400 23.5  27.9  3.5  3.1  75.6  15681.9  0.0470  640 

Model: BBTRZ
Specifications: 4 × 1.5–4 × 400 mm²
4-core cable
Voltage rating: 0.6/1 kV

Specifications and Structural Description of 4-core Flexible Mineral-Insulated Fire-Resistant Cables

ysrgtubi1787555230 1. Copper conductor
2. Mineral-composite insulation
3. Halogen-free filler strip
4. Fire-resistant layer
5. Wrapping tape
6. Low-smoke, halogen-free, flame-retardant sheath

Number of cores × cross-sectional area
(mm²)
Outer diameter of conductor
(mm)
Insulation outer diameter
(mm)
Thickness of inorganic mineral fireproof layer
(mm)
Outer sheath thickness
(mm)
Cable reference outer diameter
(mm)
Approximate weight of cable
(kg/km)
DC resistance of a conductor at 20 °C
(Ω/km)
Cable current-carrying capacity in air at an ambient temperature of 40 °C
4×2.5 1.75  3.6  1.5  1.7  17.2  412.8  7.41  28 
4×4 2.2  4.0  1.5  1.7  18.3  502.7  4.61  37 
4×6 2.7  4.5  1.5  1.7  19.5  615.7  3.08  47 
4×10 4.0  5.8  2.0  1.7  23.6  937.5  1.83  65 
4×16 5.0  6.8  2.0  1.7  26.0  1254.2  1.15  84 
4×25 6.0  8.2  2.0  1.8  29.6  1751.0  0.727  110 
4×35 7.1  9.3  2.5  1.9  33.5  2349.7  0.524  135 
4×50 8.3  10.7  2.5  2.0  37.1  3096.7  0.387  170 
4×70 10.0  12.6  2.5  2.1  42.0  4119.6  0.268  215 
4×95 11.6  14.2  3.0  2.3  47.1  5427.1  0.193  265 
4×120 12.7  15.5  3.0  2.4  50.5  6577.1  0.153  310 
4×150 14.6  17.8  3.0  2.6  56.4  8142.8  0.124  350 
4×185 16.2  19.8  3.0  2.7  61.5  9864.9  0.0991  405 
4×240 18.5  22.3  3.0  2.9  67.9  12435.9  0.0754  480 
4×300 20.7  24.7  3.5  3.1  75.2  15440.9  0.0601  555 
4×400 23.5  27.9  3.5  3.4  83.4  19961.2  0.0470  640 

Model: BBTRZ
Specifications: 5×1.5–5×400 mm²
5-core cable
Voltage rating: 0.6/1 kV

Specifications and Structural Description of 5-core Flexible Mineral-Insulated Fire-Resistant Cables

igasfnfw1787555796 1. Copper conductor
2. Mineral-composite insulation
3. Halogen-free filler strip
4. Fire-resistant layer
5. Wrapping tape
6. Low-smoke, halogen-free, flame-retardant sheath

Number of cores × cross-sectional area
(mm²)
Outer diameter of conductor
(mm)
Insulation outer diameter
(mm)
Thickness of inorganic mineral fireproof layer
(mm)
Outer sheath thickness
(mm)
Cable reference outer diameter
(mm)
Approximate weight of cable
(kg/km)
DC resistance of a conductor at 20 °C
(Ω/km)
Cable current-carrying capacity in air at an ambient temperature of 40 °C
5×2.5 1.75  3.6  1.5  1.7  18.3  473.5  7.41  28 
5×4 2.2  4.0  1.5  1.7  19.5  582.4  4.61  37 
5×6 2.7  4.5  2.0  1.7  21.9  780.4  3.08  47 
5×10 4.0  5.8  2.0  1.7  25.4  1100.3  1.83  65 
5×16 5.0  6.8  2.0  1.7  28.2  1494.9  1.15  84 
5×25 6.0  8.2  2.5  1.9  33.3  2204.2  0.727  110 
5×35 7.1  9.3  2.5  2.0  36.5  2824.3  0.524  135 
5×50 8.3  10.7  2.5  2.1  40.5  3740.6  0.387  170 
5×70 10.0  12.6  3.0  2.3  47.0  5140.2  0.268  215 
5×95 11.6  14.2  3.0  2.4  51.6  6587.2  0.193  265 
5×120 12.7  15.5  3.0  2.5  55.3  8004.4  0.153  310 
5×150 14.6  17.8  3.0  2.7  62.0  9927.0  0.124  350 
5×185 16.2  19.8  3.0  2.9  67.7  12045.9  0.0991  405 
5×240 18.5  22.3  3.5  3.2  76.0  15451.0  0.0754  480 
5×300 20.7  24.7  3.5  3.4  82.8  18889.1  0.0601  555 
5×400 23.5  27.9  3.5  3.6  92.0  24474.6  0.0470  640 

Model: BBTRZ
Specifications: 4×2.5+1×1.5 to 4×400+1×240 mm²
4+1-core cable
Voltage rating: 0.6/1 kV

Specifications and Structural Description of 4+1-core Flexible Mineral-Insulated Fire-Resistant Cables

vgkjyhlp1787556319 1. Copper conductor
2. Mineral-composite insulation
3. Halogen-free filler strip
4. Fire-resistant layer
5. Wrapping tape
6. Low-smoke, halogen-free, flame-retardant sheath

Number of cores × cross-sectional area
(mm²)

Outer diameter of conductor
(mm)
Insulation outer diameter
(mm)
Thickness of inorganic mineral fireproof layer
(mm)

Outer sheath thickness
(mm)

Cable reference outer diameter
(mm)

Approximate weight of cable
(kg/km)

DC resistance of a conductor at 20 °C
(Ω/km)
Cable current-carrying capacity in air at an ambient temperature of 40 °C
Main conductor Neutral wire Main conductor Neutral wire Main conductor Neutral wire
4×4+1×25 2.2  1.75   4.0  3.6  1.5  1.7  19.3  566.2  4.61  7.41  37 
4×6+1×4 2.7  2.2   4.5  4.0  1.5  1.7  20.6  699.1  3.08  4.61  47 
4×10+1×6 4.0  2.7   5.8  4.5  2.0  1.7  24.7  1033.4  1.83  3.08  65 
4×16+1×10 5.0  4.0   6.8  5.8  2.0  1.7  27.7  1422.8  1.15  1.83  84 
4×25+1×16 6.0  5.0   8.2  6.8  2.0  1.8  31.4  1986.5  0.727  1.15  110 
4×35+1×16 7.1  5.0   9.3  6.8  2.5  1.9  35.8  2722.7  0.524  1.15  135 
4×50+1×25 8.3  6.0  10.7  8.2  2.5  2.1  39.7  3580.7  0387  0.727  170 
4×70+1×35 10.0  7.1  12.6  9.3  3.0  2.2  45.9  4906.2  0268  0.524  215 
4×95+1×50 11.6  8.3  14.2  10.7  3.0  2.4  50.7  6351.1  0.193  0.387  265 
4×120+1×70 12.7  10.0  15.5  12.6  3.0  2.5  54.6  7808.7  0.153  0268  310 
4×150+1×70 14.6  10.0  17.8  12.6  3.0  2.7  60.6  9604.5  0.124  0268  350 
4×185+1×95 16.2  11.6  19.8  14.2  3.0  2.9  66.6  11737.7  0.0991  0.193  405 
4×240+1×120 18.5  12.7  22.3  15.5  3.5  3.1  74.5  14938.7  0.0754  0.153  480 
4×300+1×150 20.7  14.6  24.7  17.8  3.5  3.3  81.5  18389.1  0.0601  0.124  555 
4×400+1×240 23.5  18.5  27.9  22.3  3.5  3.6  90.2  23547.5  0.0470  00754 640 

Model: BBTRZ
Specifications: 3×2.5+1×1.5 to 3×400+1×240 mm²
3+1-core cable
Voltage rating: 0.6/1 kV

Specifications and Structural Description of 3+1-core Flexible Mineral-Insulated Fire-Resistant Cables

pesbbkrz1787557145 1. Copper conductor
2. Mineral-composite insulation
3. Halogen-free filler strip
4. Fire-resistant layer
5. Wrapping tape
6. Low-smoke, halogen-free, flame-retardant sheath

Number of cores × cross-sectional area
(mm²)

Outer diameter of conductor
(mm)
Insulation outer diameter
(mm)
Thickness of inorganic mineral fireproof layer
(mm)

Outer sheath thickness
(mm)

Cable reference outer diameter
(mm)

Approximate weight of cable
(kg/km)

DC resistance of a conductor at 20 °C
(Ω/km)
Cable current-carrying capacity in air at an ambient temperature of 40 °C
Main conductor Neutral wire Main conductor Neutral wire Main conductor Neutral wire
3×4+1×25 2.2  1.75  4.0  3.6  1.5  1.7  18.0    496.4  4.61  741  37 
3×6+1×4 2.7  2.2  4.5  4.0  1.5  1.7  19.2    607.4  308  4.61  47 
3×10+1×6 4.0  2.7  5.8  4.5  2.0  1.7  22.8    889.3  183  3.08  65 
3×16+1×10 5.0  4.0  6.8  5.8  2.0  1.7  25.5    1210.9  1.15  183  84 
3×25+1×16 6.0  5.0  8.2  6.8  2.0  1.7  28.8    1673.1  0.727  1.15  110 
3×35+1×25 7.1  5.0  9.3  6.8  2.0  1.8  31.8    2198.1  0524  1.15  135 
3×50+1×25 8.3  6.0  10.7  8.2  2.5  2.0  36.3    2999.6  0.387  0.727  170 
3×70+1×35 10.0  7.1  12.6  9.3  2.5  2.1  40.8    3975.1  0268  0524  215 
3×95+1×50 11.6  8.3  14.2  10.7  3.0  2.3  46.2    5299.7  0.193  0387  265 
3×120+1×70 12.7  10.0  15.5  12.6  3.0  2.4  49.8    6510.8  0.153  0268  310 
3×150+1×70 14.6  10.0  17.8  12.6  3.0  2.5  55.0    7991.5  0.124  0268  350 
3×185+1×95 16.2  11.6  19.8  14.2  3.0  2.7  60.4    9767.5  00991 0.193  405 
3×240+1×120 18.5  12.7  22.3  15.5  3.0  2.9  66.5  12193.7  00754 0.153  480 
3×300+1×150 20.7  14.6  24.7  17.8  3.0  3.1  72.7  15031.6  0.0601  0.124  555 
3×400+1×240 23.5  18.5  27.9  22.3  3.5  3.3  81.5  19441.7  0.0470  0.0754  640 

Model: BBTRZ
Specifications: 3×2.5+2×1.5 to 3×400+2×240 mm²
3+2-core cable
Voltage rating: 0.6/1 kV

Specifications and Structural Description of 3+2-core Flexible Mineral-Insulated Fire-Resistant Cables

denwbujf1787557344 1. Copper conductor
2. Mineral-composite insulation
3. Halogen-free filler strip
4. Fire-resistant layer
5. Wrapping tape
6. Low-smoke, halogen-free, flame-retardant sheath

Number of cores × cross-sectional area
(mm²)

Outer diameter of conductor
(mm)
Insulation outer diameter
(mm)
Thickness of inorganic mineral fireproof layer
(mm)

Outer sheath thickness
(mm)

Cable reference outer diameter
(mm)

Approximate weight of cable
(kg/km)

DC resistance of a conductor at 20 °C
(Ω/km)
Cable current-carrying capacity in air at an ambient temperature of 40 °C
Main conductor Neutral wire Main conductor Neutral wire Main conductor Neutral wire
3×4+2×25 2.2  1.75  4.0  3.6  1.5  1.7  19.0  553.1  4.61  741  37 
3×6+2×4 2.7  2.2  4.5  4.0  1.5  1.7  20.3  682.4  3.08  461  47 
3×10+2×6 4.0  2.7  5.8  4.5  2.0  1.7  24.0  973.9  183  308  65 
3×16+2×10 5.0  4.0  6.8  5.8  2.0  1.7  27.1  1359.8  1.15  1.83  84 
3×25+2×16 6.0  5.0  8.2  6.8  2.0  1.8  30.6  1884.5  0.727  1.15  110 
3×35+2×25 7.1  5.0  9.3  6.8  2.5  1.9  35.2  2636.9  0524  1.15  135 
3×50+2×25 8.3  6.0  10.7  8.2  2.5  2.0  38.9  3443.4  0387  0.727  170 
3×70+2×35 10.0  7.1  12.6  9.3  2.5  2.2  43.8  4566.0  0268  0.524  215 
3×95+2×50 11.6  8.3  14.2  10.7  3.0  2.4  49.8  6150.3  0.193  0387  265 
3×120+2×70 12.7  10.0  15.5  12.6  3.0  2.5  53.8  7651.4  0.153  0268  310 
3×150+2×70 14.6  10.0  17.8  12.6  3.0  2.6  59.3  9340.9  0.124  0268  350 
3×185+2×95 16.2  11.6  19.8  14.2  3.0  2.8  65.4  11496.3  00991 0.193  405 
3×240+2×120 18.5  12.7  22.3  15.5  3.0  3.0  72.0  14287.0  00754 0.153  480 
3×300+2×150 20.7  14.6  24.7  17.8  3.5  3.3  80.1  17988.2  0.0601  0.124  555 
3×400+2×240 23.5  18.5  27.9  22.3  3.5  3.5  88.4  22753.6  0.0470  0.0754  640 

1. What is Flexible Mineral Insulated Cable used for?
Flexible Mineral Insulated Cable is used in fire safety power systems requiring continuous operation under high-temperature conditions, including buildings, hospitals, tunnels, and industrial facilities.

2. What are the advantages of Flexible MI Cable compared with traditional fire-resistant cables?
Flexible MI Cable provides mineral insulation fire protection with easier installation, longer continuous lengths, and reduced connection points.

3. What makes MI Fire Resistant Cable suitable for emergency power systems?
MI Fire Resistant Cable can maintain electrical operation during fire conditions, helping support critical equipment and safety systems.

4. Why is Fire Survival Cable used in important projects?
Fire Survival Cable helps maintain power supply during fire emergencies, supporting evacuation, firefighting, and emergency response systems.

5. Can BBTRZ cable specifications be customized?
Yes. Custom options include conductor size, cable structure, printing, length, and packaging according to project requirements.

6. What is the delivery time for customized orders?
The production period is generally 20–40 days, depending on order quantity and customization requirements.

Hongsheng Wire and Cable Co., Ltd.
  • 0 Year

    Founded In

  • 0

    Factory Area

  • 0

    Current Employees

Our Story
Tailored Cable Solutions Massive Annual Output Sustainable Eco Design

Located in the coastal city of Taizhou and founded in 1983, HongSheng Wire And Cable Co., Ltd. is committed to the cutting-edge development of new wire and cable products. As a key enterprise of Zhejiang Province integrating industry, commerce, trade, production, academia, and research, the company is a trusted supplier to Sinopec, CNOOC, and the Shanghai World Expo, and maintains long-term cooperation with renowned research institutes and universities. Products can be designed and manufactured according to GB, IEC, BS, DIN, or custom specifications, and have been widely used in major projects both domestic and international.

Guided by the philosophy of "Quality First, Customer Supreme, Sincere Service," and driven by the belief "Great Vision, Success in Quality," we offer one-stop, high-quality products and services to our customers.

Certificate Of Honor
  • Certificate Of Conformity
  • Verification Of Compliance
  • Quality Management System Certificate
  • Quality Management System Certificate
  • China Compulsory Certification Certificate
  • China Compulsory Certification Certificate
  • Business License
  • Zhejiang Provincial Specialized, Refined, Unique and Innovative Small and Medium-sized Enterprises
  • High-tech Enterprise
  • National Industrial Product Production License
OUR NEWS
Pay Attention To Our Latest News and Exhibitions
View More
Message Feedback